Free download • PowerPoint • 65 slides

ISO 14971:2019 Risk Management Master Presentation

A complete clause-by-clause slide deck on medical device risk management — covering Clauses 4–10, 6 practical device case studies (infusion pump, hip implant, sterile scalpel, ESU, AI/ML SaMD and CGM), 5×5 risk matrix, FMEA/FTA, benefit-risk analysis and the Top 10 audit findings.

Download PPT
  • 16:9 widescreen — projects cleanly in any classroom or audit prep workshop.
  • Editable .pptx — customize with your company logo, device examples and SOP references.
  • No sign-up — free for personal and internal team training use.

What's inside

65 slides across 10 sections

Covers every ISO 14971:2019 clause with structured tables, a color-coded 5×5 risk matrix, and 6 practical medical device case studies.

SlidesSectionTopics covered
3–8Foundations & scopeEvolution (2007 vs 2019 + A11:2021), core definitions, global regulatory links (EU MDR, FDA QMSR, MDSAP, CDSCO) and lifecycle overview.
9–14Management & Risk Plan (Cl. 4)Top management policy, state of the art, team competence, Risk Management Plan (RMP), Risk Management File (RMF) and traceability.
15–21Hazard identification (Cl. 5.2–5.4)Intended use, reasonably foreseeable misuse, Annex A checklist, hazard taxonomy, causal chain + Infusion Pump & Hip Implant case studies.
22–28Risk estimation & tools (Cl. 5.5)5-level clinical severity scale, P1 × P2 probability separation, 5×5 risk matrix, PHA/FMEA/FTA, data sources + Sterile Scalpel case study.
29–33Risk evaluation (Cl. 6)Acceptability criteria, ALARP vs EU MDR AFAP principle, risk analysis table and avoiding RPN/detection traps.
34–43Risk control & verification (Cl. 7)3-tier hierarchy, implementation & effectiveness verification, newly introduced hazards, traceability, ESU & AI/ML SaMD case studies, IFU vs disclosure.
44–50Overall residual risk & BRA (Cl. 8)Holistic overall evaluation, Benefit-Risk Analysis (with stent example), life-supporting risks, IFU disclosures and multidisciplinary sign-off.
51–54Risk management review (Cl. 9)Pre-release verification, Risk Management Report (RMR) audit checklist and post-release design change control.
55–60Production & post-production (Cl. 10)Active PMS data collection, 5 RMF update triggers, EU MDR PSUR alignment, CGM adhesive complaint case study and CAPA link.
61–65Standards integration & auditsUsability (IEC 62366-1), software (IEC 62304), biocompatibility (ISO 10993-1), Top 10 Notified Body & FDA audit findings and final checklist.

Go deeper with SkillMed

Pair these slides with our free ISO 14971 certification course or the SkillMed Pro Risk Management Toolkit (Excel FMEA workbook + Word templates).